Schneider Electric G40n3a250 Gopact Mccb 400N 3P3d 250A 50Ka Ayar Sahalı Kompak Şalter
Main Range of product GoPact MCCB Product or component type Circuit breaker Product name GoPact MCCB 400 Device application Distribution Poles description 3P Protected poles description 3D [In] rated current 250 A at 40 °C [Ue] rated operational voltage 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 Suitability for isolation Yes conforming to EN/IEC 60947-2 Utilisation category Category A [Icu] rated ultimate short-circuit breaking capacity 50 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 65 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 Performance level N 50 kA 380/415 V AC Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit protection functions LI Control type Toggle Circuit breaker mounting mode Fixed Complementary [Ui] rated insulation voltage 440 V AC conforming to EN/IEC 60947-2 [Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2 [Ics] rated service short-circuit breaking capacity 50 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 65 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 Mechanical durability 15000 cycles Electrical durability 5000 cycles at 415 V In Power dissipation per pole 40 W Mounting support Backplate Mounting position Horizontal and vertical Flat on the back upside connection Front Downside connection Front Connection terminals Screw terminals Connection pitch 40 mm Protection type L : for overload protection (thermal) I : for short-circuit protection (magnetic) Trip unit rating 250 A at 40 °C Long-time pick-up adjustment type Ir (thermal protection) Adjustable [Ir] long-time protection pick-up adjustment range 0
Ürün Açıklamaları
Main Range of product GoPact MCCB Product or component type Circuit breaker Product name GoPact MCCB 400 Device application Distribution Poles description 3P Protected poles description 3D [In] rated current 250 A at 40 °C [Ue] rated operational voltage 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 Suitability for isolation Yes conforming to EN/IEC 60947-2 Utilisation category Category A [Icu] rated ultimate short-circuit breaking capacity 50 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 65 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 Performance level N 50 kA 380/415 V AC Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit protection functions LI Control type Toggle Circuit breaker mounting mode Fixed Complementary [Ui] rated insulation voltage 440 V AC conforming to EN/IEC 60947-2 [Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2 [Ics] rated service short-circuit breaking capacity 50 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 65 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 Mechanical durability 15000 cycles Electrical durability 5000 cycles at 415 V In Power dissipation per pole 40 W Mounting support Backplate Mounting position Horizontal and vertical Flat on the back upside connection Front Downside connection Front Connection terminals Screw terminals Connection pitch 40 mm Protection type L : for overload protection (thermal) I : for short-circuit protection (magnetic) Trip unit rating 250 A at 40 °C Long-time pick-up adjustment type Ir (thermal protection) Adjustable [Ir] long-time protection pick-up adjustment range 0
7
1 x In Long-time protection delay adjustment type tr Fixed Instantaneous protection pick-up adjustment type Ii Fixed [Ii] instantaneous protection pick-up adjustment range 12 x In Width (W) 120 mm Height (H) 205 mm Depth (D) 105 mm Net weight 3
5 kg Colour Grey (RAL 7035) Environment Standards EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H